#// FILENAME
#//   smiCmZone_Legend.txt
#//
#// PURPOSE:
#//   Intrepid-II Controller Zone Record File Description
#//
#// HISTORY:
#//   June 12, 2008 : JFD :
#//         Added inputs[] 4th parameter for relay input number
#//         Auxilliary Alarms and Line faults do not support a 
#//         range of input relays
#//
#//   May 30, 2008 : JFD : 
#//         Added zoneInuse flag, 
#//         Switched order of zoneState, zoneName, zoneComment
#//         Changed MicroPoint-II device type from MP_II to PM_II
#//         Removed 4th column of output assignment
#//
#// ---------------------------------------------------------------------
#// CVS KEYWORDS:  Automatically generated please do not edit!
#// ---------------------------------------------------------------------
#//   $Source: /usr/local/cvsroot/cm_II/smi/config/zones/smiCmZone_Legend.txt,v $
#//   $Revision: 1.4 $
#//   $Date: 2008/07/25 22:23:54 $
#//
#// +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
#//
#// =======================================================================
#//                   DESCRIPTION OF FIELDS
#// =======================================================================  
#//   zoneInuse   = zone has been created ( 0 = free, 1= created )
#//   zoneId      = zone record number identifier ( 0..255 )
#//   zoneState   = NA, SECURE, ACCESSIBLE
#//   zoneName    = 80 character null terminated ascii string
#//   zoneComment = 80 character null terminated ascii string
#//
#//----------------------------------------------------------------------
#// input_1-8 legend
#//----------------------------------------------------------------------
#//   input_1/8  = line format = contains 7 columns
#//   column_1 = device_type
#//   column_2 = node_address
#//   column_3 = input_type
#//   column_4 = parm1
#//   column_5 = parm2
#//   column_6 = parm3
#//   column_7 = parm4
#//
#//   device_type = NA, PM_II, ROM_II_16, ROM_II_8, AIM_II_8, MTP_II
#//     where:
#//         NA        = not assigned
#//         PM_II     = Intrepid-II MicroPoint processor
#//         ROM_II_16 = Intrepid-II Relay 16 Output Module
#//         ROM_II_8  = Intrepid-II Relay 8 Output Module
#//         AIM_II_8  = Intrepid-II Alarm 8 Input Module
#//         MTP_II     = Intrepid-II MicroTrack processor
#//
#//   node_address = a number between -1 and 239, -1 is unassigned
#//   input_type = NA, CF, TA, SC, SF, IA, IF, SV, or TR
#//        where:
#//         NA = not assigned
#//         CF = communication failure
#//         CP = compromized alarm
#//         TA = tamper alarm
#//         SC = sensor cable subcell alarm
#//         SF = sensor cable fault
#//         IA = auxilliary input alarm
#//         IF = line input fault
#//         SV = maintenance service alarm (IST connected )
#//         TR = trap alarm
#//
#//   if ( input_type ) == ( TA or CP or CF or SV ) then no parameters
#//
#//   if ( input_type ) == ( SC ) then 
#//       parm1 = cableId ( -1= unassigned, 0=cableA or 1=cableB )
#//       parm2 = start subcell ( -1 to 255, -1 = unassigned )
#//       parm3 = end subcell ( -1 to 255 , -1 = unassigned)
#//
#//   if ( input_type ) == ( SF ) then
#//       parm1 = cableId ( -1= unassigned, 0=cableA or 1=cableB )
#//
#//   if ( input_type ) == ( IA or IF ) then
#//       parm4 = input relay number  ( -1 to 16 ,-1= unassigned )
#//
#//--------------------------------------------------------------------------
#//   relay_out_1-8 legend
#// -------------------------------------------------------------------------
#//   relay_out_1/8 = line format containing 3 columns 
#//   column_1 = device_type, 
#//   column_2 = node_address, 
#//   column_3 = relay_output_nbr 
#//
#//   where :
#//   device_type = NA, ROM_II_16, or ROM_II_8
#//   node_address = a number between -1 and 239, -1 unassigned
#//   relay_output_nbr = a number from -1 to 32, -1 = unassigned
#//
#/////////////////////////////////////////////////////////////////////////// 